AGA GC Podręcznik Użytkownika Strona 7

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 24
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 6
In the event of a power failure, the AIMS controls will not work until the power is restored. You
can still use your appliance as a conventional AGA.
7
TO LIGHT THE BURNER
CAUTION: BEFORE LIGHTING: ENSURE KNOB (A) IS IN THE OFF POSITION (SEE FIG. 5).
ALSO ENSURE GAS SUPPLY TO COOKER IS ON, AND THE GAS SERVICE COCK (C) IS
IN THE ON POSITION (SEE FIG. 3), AND THE ELECTRICITY SUPPLY TO THE AGA IS
SWITCHED ON.
LIGHTING PROCEDURE - SEE FIGS. 4 - 10
1. The main burner gas flow is set with the ‘temperature’ knob (B) (See Fig. 4). First, ensure
both knobs are turned fully clockwise. Knob (A) to the OFF position and knob (B) to the
minimum setting (See Fig. 4).
2. Turn ON/OFF knob (A) slightly anti-clockwise towards the IGNITION position ( ) until
reaching stop, press down and hold for 5 seconds (gas flows only to the pilot burner). (See
Fig. 6).
3. Continue pressing down knob (A) while turning further anti-clockwise to the PILOT position
(this activates the piezo), continue to hold down for 10 seconds after pilot burner has been lit.
(If the pilot does not light, steps 2 and 3 can be repeated). (See Fig. 7).
4. Upon lighting, release knob and turn further anti-clockwise to the ON position (large flame
symbol) (See Fig. 8). Pilot gas flows and mains gas flows according to the temperature
setting (knob B).
5. Turn the temperature knob (B) slightly anti-clockwise into the white band (LOW FIRE
position). Leave in the low fire position for at least 30 minutes
(See Fig. 9).
NOTE: ‘LOW FIRE’ position is attained by turning knob (B) gradually into the white band, until
SMALL FLAME is observed through viewing window (H). (See Fig. 3).
6. After 30 minutes rotate control knob (B) anti-clockwise to the mid-position of the green band
for normal running. (See Fig. 10).
NOTE: After several hours the heat indicator should be within the black band on the AIMS
handset ‘INFORMATION’ screen. It may be necessary to adjust the control knob slightly in the
green band to achieve this, allow the cooker to stabilise for at least 4 hours before attempting
any further adjustment.
When the cooker is lit from cold, moisture may form on the enamel which should be wiped off to
prevent staining.
IF THE FLAME HAS EXTINGUISHED FOR WHATEVER REASON, WAIT THREE MINUTES
(MINIMUM) BEFORE RE-LIGHTING.
NOTE: IF THE PILOT EXTINGUISHES
For safety purposes a flue safety device (6) is fitted.
This will only operate in adverse flue conditions, it should be checked and if necessary
depressed. If this problem persists contact your local engineer to determine and rectify the
cause.
TO EXTINGUISH THE BURNER
1. Turn ON/OFF knob (A) clockwise until reaching stop (PILOT) position.
2. Press down slightly and continue turning clockwise from pilot position to the OFF position
(See Fig. 5).
NOTE: LPG APPLIANCE ONLY. When the cooker is turned off a noticeably loud pop will
be heard. This is quite normal.
When the burner has cooled sufficiently, pilot lighting procedure may be repeated.
POWER FAILURE (OPEN FLUE MODELS ONLY)